Showing results: 31 - 45 of 283 items found.
-
PCIe-7396 -
ADLINK Technology Inc.
The PCIe-7396 is a 96-bit parallel digital input/output (DIO) card esigned for industrial applications. The plug and play feature of PCI Express Bus architecture makes it easy for users to install the PCIe-7396 on their systems quickly.
-
PCI-9524 -
ADLINK Technology Inc.
The PCI-9524 is a robust, multi-purpose module designed for turnkey material test systems (MTS). Equipped with four strain gauge-based transducer input channels, four general purpose analog input channels, and a 3-axis motion controller, the PCI-9524 delivers a complete hardware solution for MTS manufacturers. The PCI-9524 easily integrates physical quantity measurement and implements strategy of close-loop control in a single module package. For transducer measurement, the PCI-9524 supports sensitivity from 1.0 mV/V to 4.0 mV/V and provides a 1/200000 accuracy of measurement of full scale. These features make the PCI-9524 suitable for precise measurement in large-scale transducers.
-
43-765-004 -
Pickering Interfaces Ltd.
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-001 -
Pickering Interfaces Ltd.
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-002 -
Pickering Interfaces Ltd.
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
43-765-003 -
Pickering Interfaces Ltd.
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
777306-01 -
NI
The PCI‑6704 is a static analog output device that you can use for software‑timed voltage and current output applications.
-
784483-01 -
NI
PXIe, 24-Channel, ±24 V, 50 mA PXI Source Measure Unit—The PXIe-4163 is a high-density source measure unit (SMU). It features 4-quadrant operation with a current resolution of 100 pA and the ability to sample up to 100 kS/s. The module also offers the ability to maximize stability and measurement accuracy with SourceAdapt, which allows you to custom-tune the transient response to match the characteristics of any load. The PXI-4163 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.
-
785680-01 -
NI
PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. It also features guard terminals to remove the effects of leakage currents and parasitic capacitances. Additionally, the PXIe-4162 can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4162 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.
-
781348-01 -
NI
32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.
-
781346-01 -
NI
25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
783866-01 -
NI
24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4303 is a filtered input module for voltage, thermocouple, and current measurements. The module offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
783865-01 -
NI
24-Bit, 32-Channel, 5 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4302 is a filtered input module for voltage, thermocouple, and current measurements. The module has an A/D converter per channel to enable a simultaneous sample rate of 5 kS/s. The PXIe‑4302 offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
784471-01 -
NI
28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module—The PXIe-4309 samples up to 32 differential channels and multiplexes the analog input channels across eight simultaneously sampling ADCs. The module samples eight input channels up to 2 MS/s/ch (single channel per ADC), and 32 input channels up to 100 kS/s/ch (four channels per ADC). The module's flexible resolution ranges from 18 bits at 2 MS/s/ch to 28 bits at 2 S/s/ch. The module features on-board signal averaging and filtering, auto-zero measurement switching, and a chopping mode that uses a pair of channels to provide high levels of noise rejection and to enable accurate and repeatable nano-volt measurements.
-
782118-01 -
NI
20-Channel, 24-Bit PXI Temperature Input Module—The NI PXIe‑4357 input module provides integrated data acquisition and signal conditioning for 2‑, 3‑, or 4‑wire resistance temperature detector (RTD) measurements. It offers both high-speed and high-resolution modes. It provides per channel software-programmable configurations and automatically scale measured data into engineering units.